Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Inherit Metab Dis ; 46(6): 1159-1169, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37747296

RESUMO

Measurement of plasmalogens is useful for the biochemical diagnosis of rhizomelic chondrodysplasia punctata (RCDP) and is also informative for Zellweger spectrum disorders (ZSD). We have developed a test method for the simultaneous quantitation of C16:0, C18:0, and C018:1 plasmalogen (PG) species and their corresponding fatty acids (FAs) in dried blood spots (DBS) and erythrocytes (RBC) by using capillary gas chromatography-mass spectrometry. Normal reference ranges for measured markers and 10 calculated ratios were established by the analysis of 720 and 473 unaffected DBS and RBC samples, respectively. Determination of preliminary disease ranges was made by using 45 samples from 43 unique patients: RCDP type 1 (DBS: 1 mild, 17 severe; RBC: 1 mild, 6 severe), RCDP type 2 (DBS: 2 mild, 1 severe; RBC: 2 severe), RCDP type 3 (DBS: 1 severe), RCDP type 4 (RBC: 2 severe), and ZSD (DBS: 3 severe; RBC: 2 mild, 7 severe). Postanalytical interpretive tools in Collaborative Laboratory Integrated Reports (CLIR) were used to generate an integrated score and a likelihood of disease. In conjunction with a review of clinical phenotype, phytanic acid, and very long-chain FA test results, the CLIR analysis allowed for differentiation between RCDP and ZSD. Data will continue to be gathered to improve CLIR analysis as more samples from affected patients with variable disease severity are analyzed. The addition of DBS analysis of PGs may allow for at-home specimen collection and second-tier testing for newborn screening programs.


Assuntos
Condrodisplasia Punctata Rizomélica , Transtornos Peroxissômicos , Síndrome de Zellweger , Recém-Nascido , Humanos , Plasmalogênios , Condrodisplasia Punctata Rizomélica/genética , Transtornos Peroxissômicos/diagnóstico , Ácido Fitânico
2.
JIMD Rep ; 60(1): 67-74, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34258142

RESUMO

BACKGROUND: Glutaric acidemia type I (GA1) is an organic acidemia that is often unrecognized in the newborn period until patients suffer an acute encephalopathic crisis, which can be mistaken for nonaccidental trauma. Presymptomatic identification of GA1 patients is possible by newborn screening (NBS). However, the biochemical "low-excretor" (LE) phenotype with nearly normal levels of disease metabolites can be overlooked, which may result in untreated disease and irreversible neurological sequelae. The LE phenotype is also a potential source of false negative (FN) NBS results that merits further investigation. METHODS: Samples from six LE GA1 patients were analyzed by biochemical and molecular methods and newborn screen outcomes were retrospectively investigated. RESULTS: Five LE GA1 patients were identified that had normal NBS results and three of these presented clinically with GA1 symptoms. One additional symptomatic patient was identified who did not undergo screening. Semiquantitative urine organic acid analysis was consistent with a GA1 diagnosis in two (33%) of the six patients, while plasma glutarylcarnitine was elevated in four (67%) of the six and urine glutarylcarnitine was elevated in four (80%) of five patients. Five GCDH variants were identified in these patients; three of which have not been previously linked to the biochemical LE phenotype. CONCLUSIONS: The data presented here raise awareness of potential FN NBS results for LE GA1 patients. The LE phenotype is not protective against adverse clinical outcomes, and the possibility of FN NBS results calls for high vigilance amongst clinicians, even in the setting of a normal NBS result.

3.
Am J Med Genet A ; 185(1): 213-218, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33044030

RESUMO

Glycosylation is a critical post/peri-translational modification required for the appropriate development and function of the immune system. As an example, abnormalities in glycosylation can cause antibody deficiency and reduced lymphocyte signaling, although the phenotype can be complex given the diverse roles of glycosylation. Human MGAT2 encodes N-acetylglucosaminyltransferase II, which is a critical enzyme in the processing of oligomannose to complex N-glycans. Complex N-glycans are essential for immune system functionality, but only one individual with MGAT2-CDG has been described to have an abnormal immunologic evaluation. MGAT2-CDG (CDG-IIa) is a congenital disorder of glycosylation (CDG) associated with profound global developmental disability, hypotonia, early onset epilepsy, and other multisystem manifestations. Here, we report a 4-year old female with MGAT2-CDG due to a novel homozygous pathogenic variant in MGAT2, a 4-base pair deletion, c.1006_1009delGACA. In addition to clinical features previously described in MGAT2-CDG, she experienced episodic asystole, persistent hypogammaglobulinemia, and defective ex vivo mitogen and antigen proliferative responses, but intact specific vaccine antibody titers. Her infection history has been mild despite the testing abnormalities. We compare this patient to the 15 previously reported patients in the literature, thus expanding both the genotypic and phenotypic spectrum for MGAT2-CDG.


Assuntos
Arritmias Cardíacas/genética , Defeitos Congênitos da Glicosilação/genética , Doenças do Sistema Imunitário/genética , N-Acetilglucosaminiltransferases/genética , Arritmias Cardíacas/complicações , Arritmias Cardíacas/imunologia , Arritmias Cardíacas/patologia , Pré-Escolar , Defeitos Congênitos da Glicosilação/complicações , Defeitos Congênitos da Glicosilação/imunologia , Defeitos Congênitos da Glicosilação/patologia , Feminino , Glicosilação , Homozigoto , Humanos , Doenças do Sistema Imunitário/complicações , Doenças do Sistema Imunitário/imunologia , Doenças do Sistema Imunitário/patologia , Mutação/genética , N-Acetilglucosaminiltransferases/imunologia , Fenótipo
4.
Int J Neonatal Screen ; 6(2): 33, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33073028

RESUMO

The expansion of the recommend uniform screening panel to include more than 50 primary and secondary target conditions has resulted in a substantial increase of false positive results. As an alternative to subjective manipulation of cutoff values and overutilization of molecular testing, here we describe the performance outcome of an algorithm for disorders of methionine, cobalamin, and propionate metabolism that includes: (1) first tier screening inclusive of the broadest available spectrum of markers measured by tandem mass spectrometry; (2) integration of all results into a score of likelihood of disease for each target condition calculated by post-analytical interpretive tools created byCollaborative Laboratory Integrated Reports (CLIR), a multivariate pattern recognition software; and (3) further evaluation of abnormal scores by a second tier test measuring homocysteine, methylmalonic acid, and methylcitric acid. This approach can consistently reduce false positive rates to a <0.01% level, which is the threshold of precision newborn screening. We postulate that broader adoption of this algorithm could lead to substantial savings in health care expenditures. More importantly, it could prevent the stress and anxiety experienced by many families when faced with an abnormal newborn screening result that is later resolved as a false positive outcome.

5.
Int J Neonatal Screen ; 6(2)2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32802993

RESUMO

Newborn screening for one or more lysosomal disorders has been implemented in several US states, Japan and Taiwan by multiplexed enzyme assays using either tandem mass spectrometry or digital microfluidics. Another multiplex assay making use of immunocapture technology has also been proposed. To investigate the potential variability in performance of these analytical approaches, we implemented three high-throughput screening assays for the simultaneous screening for four lysosomal disorders: Fabry disease, Gaucher disease, mucopolysaccharidosis type I, and Pompe disease. These assays were tested in a prospective comparative effectiveness study using nearly 100,000 residual newborn dried blood spot specimens. In addition, 2nd tier enzyme assays and confirmatory molecular genetic testing were employed. Post-analytical interpretive tools were created using the software Collaborative Laboratory Integrated Reports (CLIR) to determine its ability to improve the performance of each assay vs. the traditional result interpretation based on analyte-specific reference ranges and cutoffs. This study showed that all three platforms have high sensitivity, and the application of CLIR tools markedly improves the performance of each platform while reducing the need for 2nd tier testing by 66% to 95%. Moreover, the addition of disease-specific biochemical 2nd tier tests ensures the lowest false positive rates and the highest positive predictive values for any platform.

6.
Mol Genet Metab ; 130(4): 247-254, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32546364

RESUMO

BACKGROUND: The prognosis of patients with Hereditary Tyrosinemia Type 1 (HT-1) has greatly improved with early detection through newborn screening and the introduction of nitisinone (NTBC) therapy. A recent guideline calls for periodic monitoring of biochemical markers and NTBC levels to tailor treatment; however, this is currently only achieved through a combination of clinical laboratory tests. We developed a multiplexed assay measuring relevant amino acids, succinylacetone (SUAC), and NTBC in dried blood spots (DBS) to facilitate treatment monitoring. METHODS: Tyrosine, phenylalanine, methionine, NTBC and SUAC were eluted from DBS with methanol containing internal standards for each analyte and analyzed by liquid chromatography tandem mass spectrometry over 6.5 min in the multiple reaction monitoring positive mode. RESULTS: Pre-analytical and analytical factors were studied and demonstrated a reliable assay. Chromatography resolved an unknown substance that falsely elevates SUAC concentrations and was present in all samples. To establish control and disease ranges, the method was applied to DBS collected from controls (n = 284) and affected patients before (n = 2) and after initiation of treatment (n = 29). In the treated patients SUAC concentrations were within the normal range over a wide range of NTBC levels. CONCLUSIONS: This assay enables combined, accurate measurement of revelevant metabolites and NTBC in order to simplify treatment monitoring of patients with HT-1. In addition, the use of DBS allows for specimen collection at home to facilitate more standardization in relation to drug and dietary treatment.


Assuntos
Aminoácidos/sangue , Biomarcadores/sangue , Cicloexanonas/sangue , Heptanoatos/sangue , Laboratórios/normas , Nitrobenzoatos/sangue , Tirosinemias/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Prognóstico , Padrões de Referência , Manejo de Espécimes , Tirosinemias/sangue , Tirosinemias/genética , Adulto Jovem
8.
Genet Med ; 22(6): 1108-1118, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32089546

RESUMO

PURPOSE: Newborn screening (NBS) for Krabbe disease (KD) is performed by measurement of galactocerebrosidase (GALC) activity as the primary test. This revealed that GALC activity has poor specificity for KD. Psychosine (PSY) was proposed as a disease marker useful to reduce the false positive rate for NBS and for disease monitoring. We report a highly sensitive PSY assay that allows identification of KD patients with minimal PSY elevations. METHODS: PSY was extracted from dried blood spots or erythrocytes with methanol containing d5-PSY as internal standard, and measured by liquid chromatography-tandem mass spectrometry. RESULTS: Analysis of PSY in samples from controls (N = 209), GALC pseudodeficiency carriers (N = 55), GALC pathogenic variant carriers (N = 27), patients with infantile KD (N = 26), and patients with late-onset KD (N = 11) allowed for the development of an effective laboratory screening and diagnostic algorithm. Additional longitudinal measurements were used to track therapeutic efficacy of hematopoietic stem cell transplantion (HSCT). CONCLUSION: This study supports PSY quantitation as a critical component of NBS for KD. It helps to differentiate infantile from later onset KD variants, as well as from GALC variant and pseudodeficiency carriers. Additionally, this study provides further data that PSY measurement can be useful to monitor KD progression before and after treatment.


Assuntos
Leucodistrofia de Células Globoides , Psicosina , Teste em Amostras de Sangue Seco , Galactosilceramidase/genética , Humanos , Recém-Nascido , Leucodistrofia de Células Globoides/diagnóstico , Leucodistrofia de Células Globoides/genética , Triagem Neonatal
9.
J Appl Lab Med ; 2(1): 55-64, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33636959

RESUMO

BACKGROUND: Cystinuria is an autosomal recessive disorder resulting in poor proximal tubule reabsorption of cystine in the nephron, increasing the risk of cystine stone formation. A fast, inexpensive assay to screen for urinary cystine is needed because cystine stones are difficult to noninvasively differentiate from more common calcium-containing ones. Tandem mass spectrometry (MS/MS) is sensitive and specific but is labor-intensive and costly. Alternatively, a colorimetric assay is fast and cost-effective; however, creatinine interference is an issue. METHODS: A published cyanide-nitroprusside colorimetric assay was modified for a high-throughput microplate format. Creatinine interference was reduced using 0.1 mol/L PBS and a standard reaction time of 60 s and was further corrected using a formula derived from the slope of multiple creatinine standard curves. RESULTS: The limit of blank was determined to be 2.6 mg/L, the limit of detection 11.9 mg/L, and the limit of quantitation 15.3 mg/L. The analytic measurement range was established as 15.3-100 mg/L cystine. Intraassay and interassay CV was calculated to be 9.6% and 8.0%, respectively, for a high-level cystine concentration (83.6 mg/L). Low-level cystine (36.4 mg/L) intraassay and interassay CV was determined to be 18.1% and 17.6%, respectively. Passing-Bablok regression analysis of colorimetric vs LC-MS/MS results revealed a slope of 1.10 and y intercept of -7.14 mg/L, with an overall bias of 2% by Bland-Altman plot analysis. CONCLUSIONS: We analytically validated a rapid colorimetric assay suitable to quantify urinary cystine. The effect of thiol drugs on this assay remains to be determined.

10.
Clin Chem ; 62(9): 1248-54, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27440509

RESUMO

BACKGROUND: Newborn screening for lysosomal storage disorders (LSD) has revealed that late-onset variants of these conditions are unexpectedly frequent and therefore may evade diagnosis. We developed an efficient and cost-effective multiplex assay to diagnose six LSDs and several peroxisomal disorders in patients presenting with diverse phenotypes at any age. METHODS: Three 3-mm dried blood spot (DBS) punches were placed into individual microtiter plates. One disc was treated with a cocktail containing acid sphingomyelinase-specific substrate and internal standard (IS). To the second DBS we added a cocktail containing substrate and IS for ß-glucosidase, acid α-glucosidase, α-galactosidase A, galactocerebrosidase, and α-L-iduronidase. The third DBS was extracted with methanol containing d4-C26 lysophosphatidylcholine as IS and stored until the enzyme plates were combined and purified by liquid-liquid and solid-phase extraction. The extracts were evaporated, reconstituted with the extract from the lysophosphatidylcholine plate, and analyzed by flow injection tandem mass spectrometry. RESULTS: Reference intervals were determined by analysis of 550 samples from healthy controls. DBS from confirmed patients with 1 of the 6 LSDs (n = 33), X-adrenoleukodystrophy (n = 9), or a peroxisomal biogenesis disorder (n = 5), as well as carriers for Fabry disease (n = 17) and X-adrenoleukodystrophy (n = 5), were analyzed for assay validation. Prospective clinical testing of 578 samples revealed 25 patients affected with 1 of the detectable conditions. CONCLUSIONS: Our flow injection tandem mass spectrometry approach is amenable to high-throughput population screening for Hurler disease, Gaucher disease, Niemann-Pick A/B disease, Pompe disease, Krabbe disease, Fabry disease, X-adrenoleukodystrophy, and peroxisomal biogenesis disorder in DBS.


Assuntos
Adrenoleucodistrofia/sangue , Teste em Amostras de Sangue Seco , Doenças por Armazenamento dos Lisossomos/sangue , Adrenoleucodistrofia/diagnóstico , Humanos , Doenças por Armazenamento dos Lisossomos/diagnóstico , Espectrometria de Massas em Tandem
11.
Hum Mutat ; 37(10): 1097-105, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27397503

RESUMO

Tyrosinemia type I (TYRSN1, TYR I) is caused by fumarylacetoacetate hydrolase (FAH) deficiency and affects approximately one in 100,000 individuals worldwide. Pathogenic variants in FAH cause TYRSN1, which induces cirrhosis and can progress to hepatocellular carcinoma (HCC). TYRSN1 is characterized by the production of a pathognomonic metabolite, succinylacetone (SUAC) and is included in the Recommended Uniform Screening Panel for newborns. Treatment intervention is effective if initiated within the first month of life. Here, we describe a family with three affected children who developed HCC secondary to idiopathic hepatosplenomegaly and cirrhosis during infancy. Whole exome sequencing revealed a novel homozygous missense variant in FAH (Chr15(GRCh38):g.80162305A>G; NM_000137.2:c.424A > G; NP_000128.1:p.R142G). This novel variant involves the catalytic pocket of the enzyme, but does not result in increased SUAC or tyrosine, making the diagnosis of TYRSN1 problematic. Testing this novel variant using a rapid, in vivo somatic mouse model showed that this variant could not rescue FAH deficiency. In this case of atypical TYRSN1, we show how reliance on SUAC as a primary diagnostic test can be misleading in some patients with this disease. Augmentation of current screening for TYRSN1 with targeted sequencing of FAH is warranted in cases suggestive of the disorder.


Assuntos
Carcinoma Hepatocelular/genética , Hidrolases/genética , Cirrose Hepática/genética , Neoplasias Hepáticas/genética , Mutação de Sentido Incorreto , Tirosinemias/diagnóstico , Adolescente , Animais , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/patologia , Domínio Catalítico , Linhagem Celular Tumoral , Criança , Pré-Escolar , Modelos Animais de Doenças , Feminino , Heptanoatos/metabolismo , Humanos , Hidrolases/química , Lactente , Cirrose Hepática/complicações , Cirrose Hepática/etiologia , Cirrose Hepática/patologia , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/patologia , Masculino , Camundongos , Linhagem , Análise de Sequência de DNA , Tirosina/metabolismo , Tirosinemias/complicações , Tirosinemias/genética
12.
Mayo Clin Proc ; 91(3): 297-307, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26944241

RESUMO

OBJECTIVE: To describe the experience and outcome of performing whole-exome sequencing (WES) for resolution of patients on a diagnostic odyssey in the first 18 months of an individualized medicine clinic (IMC). PATIENTS AND METHODS: The IMC offered WES to physicians of Mayo Clinic practice for patients with suspected genetic disease. DNA specimens of the proband and relatives were submitted to WES laboratories. We developed the Genomic Odyssey Board with multidisciplinary expertise to determine the appropriateness for IMC services, review WES reports, and make the final decision about whether the exome findings explain the disease. This study took place from September 30, 2012, to March 30, 2014. RESULTS: In the first 18 consecutive months, the IMC received 82 consultation requests for patients on a diagnostic odyssey. The Genomic Odyssey Board deferred 7 cases and approved 75 cases to proceed with WES. Seventy-one patients met with an IMC genomic counselor. Fifty-one patients submitted specimens for WES testing, and the results have been received for all. There were 15 cases in which a diagnosis was made on the basis of WES findings; thus, the positive diagnostic yield of this practice was 29%. The mean cost per patient for this service was approximately $8000. Medicaid supported 27% of the patients, and 38% of patients received complete or partial insurance coverage. CONCLUSION: The significant diagnostic yield, moderate cost, and notable health marketplace acceptance for WES compared with conventional genetic testing make the former method a rational diagnostic approach for patients on a diagnostic odyssey.


Assuntos
Exoma , Testes Genéticos/economia , Testes Genéticos/métodos , Genômica , Sequenciamento de Nucleotídeos em Larga Escala , Medicina de Precisão/métodos , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Predisposição Genética para Doença , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Minnesota , Adulto Jovem
13.
Paediatr Anaesth ; 25(8): 807-817, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25943188

RESUMO

BACKGROUND: Organic acidurias (OAs) are rare inborn errors of metabolism that can present with various neurologic manifestations, propensity for acute metabolic decompensation with anion-gap metabolic acidosis, developmental delay, poor feeding, and failure to thrive. OBJECTIVE: In this case series, we outline the anesthetic management and perioperative outcomes of OA patients. METHODS: We reviewed demographic characteristics, comorbidities, and perioperative course of patients with four different OAs who underwent anesthetic care at our institution between January 1, 2000, and December 31, 2013. RESULTS: Eleven patients with OA underwent 19 anesthetic procedures, of which 13 were <2 h in duration and seven were outpatient procedures. One patient with methylmalonic acidemia developed metabolic acidosis during a 10-h procedure with substantial blood loss but lacked evidence that this acidosis could be attributed to his underlying metabolic disease. The patients who received hydration with lactated Ringer's solution and/or nitrous oxide anesthetic had a perioperative course free of metabolic complication. Two patients died within 30 days of surgery from causes likely to be unrelated to anesthetic exposure. CONCLUSIONS: Our patients with various forms of metabolically compensated OAs tolerated anesthetics for surgical procedures without metabolic decompensation, even when lactated Ringer's solution was used for hydration. Measures to prevent protein catabolism and intraoperative events that may precipitate metabolic acidosis, in addition to close monitoring of acid-base status during more extensive procedures, must be part of perioperative treatment of these patients.


Assuntos
Acidose/complicações , Erros Inatos do Metabolismo dos Aminoácidos/complicações , Anestesia/métodos , Soluções Isotônicas/administração & dosagem , Adolescente , Adulto , Erros Inatos do Metabolismo dos Aminoácidos/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Lactato de Ringer , Adulto Jovem
14.
Mol Genet Metab ; 114(1): 46-50, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25481105

RESUMO

BACKGROUND: Pre-symptomatic hematopoietic stem cell transplantation is essential to achieve best possible outcomes for patients with the childhood cerebral form of X-linked adrenoleukodystrophy (X-ALD). We describe a high-throughput method for measurement of C20-C26 lysophosphatidylcholines (LPCs) and biochemical diagnosis of X-ALD using the same dried blood spots (DBS) routinely used for newborn screening. METHODS: LPCs are extracted from 3-mm DBS punch with methanol containing an isotopically labeled LPC as internal standard. This extract is transferred to a 96-well plate, evaporated and then reconstituted in mobile phase for flow injection analysis tandem mass spectrometry (FIA-MS/MS) in selected reaction monitoring mode for measurement of four different LPCs (C20, C22, C24, C26) and the internal standard (d4-C26-LPC). Analysis time is 1.5min per sample. RESULTS: The mean CVs from the intra- and inter-assay experiments for LPCs were 6.3-15.1% for C20-LPC, 4.4-18.6% for C22-LPC and 4.5-14.3% for C24-LPC. Limits of detection were determined for C20-LPC (LOD=0.03µg/mL), C22-LPC (0.03µg/mL), C24-LPC (0.03µg/mL) and C26-LPC (0.01µg/mL). Reference ranges were established from DBS of 130 newborns and 20 adults. Samples of patients with X-ALD (n=16), peroxisomal biogenesis disorders (n=8), and X-ALD carriers (n=12) were analyzed blindly and all were correctly identified. CONCLUSION: Analysis of LPC species by FIA-MS/MS is a fast, simple and reliable method to screen for X-ALD and other peroxisomal disorders in DBS. To maximize specificity, abnormal results can be verified by a 2nd tier assay using LC-MS/MS.


Assuntos
Adrenoleucodistrofia/sangue , Teste em Amostras de Sangue Seco , Lisofosfatidilcolinas/sangue , Triagem Neonatal/métodos , Adulto , Cromatografia Líquida , Ensaios de Triagem em Larga Escala , Humanos , Recém-Nascido , Limite de Detecção , Transtornos Peroxissômicos/sangue , Valores de Referência , Espectrometria de Massas em Tandem/métodos
15.
Clin Chim Acta ; 440: 169-71, 2015 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-25463746

RESUMO

BACKGROUND: Macroenzyme complexes of serum enzymes and antibody can increase the circulating enzymatic activity and may lead to unnecessary additional testing and procedures. Laboratory physicians and scientists need to be aware of techniques to identify macroenzyme complexes when suspected. CASE REPORT: To investigate the possibility of a macro-alkaline phosphatase in the serum of a 74 year old male with persistently increased alkaline phosphatase we coupled a protein A/G agarose affinity chromatography technique with isoenzyme electrophoresis to look for the presence of macro-alkaline phosphatase. RESULTS: The majority of the alkaline phosphatase activity in the patient's serum sample was bound to the column and only a minor fraction (25%) of alkaline phosphatase activity was present in the column flow-through. The alkaline phosphatase activity was also found to co-elute with the immunoglobulins in the patient sample. The alkaline phosphatase activity in a control serum sample concurrently treated in the same manner did not bind to the column and was found in the column flow-through. CONCLUSION: The use of protein A/G agarose affinity chromatography is a rapid and simple method that can be applied to the investigation of other macro-enzyme complexes.


Assuntos
Fosfatase Alcalina/sangue , Eletroforese das Proteínas Sanguíneas/métodos , Cromatografia de Afinidade/métodos , Idoso , Análise Química do Sangue/métodos , Enzimas/sangue , Humanos , Imunoglobulina G/sangue , Isoenzimas/sangue , Masculino , Complexos Multienzimáticos/sangue
16.
Nat Genet ; 43(9): 883-6, 2011 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-21841779

RESUMO

We used exome sequencing to identify the genetic basis of combined malonic and methylmalonic aciduria (CMAMMA). We sequenced the exome of an individual with CMAMMA and followed up with sequencing of eight additional affected individuals (cases). This included one individual who was identified and diagnosed by searching an exome database. We identify mutations in ACSF3, encoding a putative methylmalonyl-CoA and malonyl-CoA synthetase as a cause of CMAMMA. We also examined a canine model of CMAMMA, which showed pathogenic mutations in a predicted ACSF3 ortholog. ACSF3 mutant alleles occur with a minor allele frequency of 0.0058 in ∼1,000 control individuals, predicting a CMAMMA population incidence of ∼1:30,000. ACSF3 deficiency is the first human disorder identified as caused by mutations in a gene encoding a member of the acyl-CoA synthetase family, a diverse group of evolutionarily conserved proteins, and may emerge as one of the more common human metabolic disorders.


Assuntos
Coenzima A Ligases/genética , Éxons , Erros Inatos do Metabolismo/genética , Adolescente , Idoso , Sequência de Aminoácidos , Carboxiliases/deficiência , Carboxiliases/genética , Pré-Escolar , Coenzima A Ligases/química , Feminino , Humanos , Masculino , Malonil Coenzima A , Ácido Metilmalônico , Pessoa de Meia-Idade , Dados de Sequência Molecular , Mutação de Sentido Incorreto
17.
J Inherit Metab Dis ; 33 Suppl 3: S349-53, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20821052

RESUMO

α-Methyl-acyl-CoA-racemase (AMACR) deficiency (OMIM 604489) is a rare peroxisomal disorder with a variable age of onset from infancy to late adulthood. We describe a 45-year-old male with a history of seizures who presented with relapsing encephalopathy. Laboratory studies revealed an elevated serum pristanic acid concentration, an elevated pristanic/phytanic acid ratio, as well as the previously described homozygous mutation in the AMACR gene, c.154T>C, consistent with AMACR deficiency. This homozygous mutation is associated with a variable phenotype ranging from neonatal cholestasis to late-onset sensorimotor neuropathy. Dietary pristanic acid restriction was attempted to improve clinical status and the patient has remained in remission for more than 16 months.


Assuntos
Erros Inatos do Metabolismo Lipídico/diagnóstico , Doenças do Sistema Nervoso/diagnóstico , Racemases e Epimerases/deficiência , Idade de Início , Biomarcadores/sangue , Análise Mutacional de DNA , Ácidos Graxos/sangue , Predisposição Genética para Doença , Homozigoto , Humanos , Leucoencefalopatias/etiologia , Erros Inatos do Metabolismo Lipídico/sangue , Erros Inatos do Metabolismo Lipídico/complicações , Erros Inatos do Metabolismo Lipídico/dietoterapia , Erros Inatos do Metabolismo Lipídico/enzimologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Mutação , Doenças do Sistema Nervoso/sangue , Doenças do Sistema Nervoso/complicações , Doenças do Sistema Nervoso/dietoterapia , Doenças do Sistema Nervoso/enzimologia , Fenótipo , Ácido Fitânico/sangue , Racemases e Epimerases/sangue , Racemases e Epimerases/genética , Indução de Remissão , Convulsões/etiologia , Resultado do Tratamento
18.
Clin Chem ; 56(11): 1686-95, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20807894

RESUMO

BACKGROUND: Newborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: The analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d(3)-MMA, d(3)-MCA, d(8)-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening. RESULTS: The 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 µmol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants. CONCLUSIONS: Application of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations.


Assuntos
Citratos/sangue , Homocisteína/sangue , Ácido Metilmalônico/sangue , Coleta de Amostras Sanguíneas , Cromatografia Líquida , Reações Falso-Positivas , Humanos , Recém-Nascido , Limite de Detecção , Triagem Neonatal , Valor Preditivo dos Testes , Valores de Referência , Espectrometria de Massas em Tandem
19.
J Pediatr ; 157(2): 271-5, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20394947

RESUMO

OBJECTIVE: To validate a 2-tier approach for newborn screening (NBS) of remethylation defects. STUDY DESIGN: The original NBS dried blood spots of 5 patients with a proven diagnosis of a remethylation disorder and 1 patient with biochemical evidence of such disorder were analyzed retrospectively to determine disease ranges for methionine (Met; 4.7-8.1 micromol/L; 1 percentile of healthy population, 11.1 micromol/L), the methionine/phenylalanine ratio (Met/Phe; 0.09-0.16; 1 percentile of healthy population, 0.22), and total homocysteine (tHcy; 42-157 micromol/L; 99 percentile of normal population, 14.7 micromol/L). These preliminary disease ranges showed a sufficient degree of segregation from healthy population data, allowing the selection of cutoff values. A simple algorithm was then developed to reflex cases to a second-tier testing for tHcy, which has been applied prospectively for 14 months. RESULTS: A total of 86 333 NBS samples were tested between January 2007 and March 2008, and 233 of them (0.27%) met the criteria for second-tier testing of tHcy. All cases revealed concentrations of tHcy <15 micromol/L and were considered unaffected. No false-negative results have been reported with a state-wide system based on 2 combined metabolic clinics and laboratories that cover the entire Minnesota population and border areas of neighboring states. CONCLUSIONS: Pending more conclusive evidence from the prospective identification of additional true-positive cases, NBS for remethylation disorders appears to be feasible with existing methodologies, with only a marginal increase of the laboratory workload.


Assuntos
Erros Inatos do Metabolismo/sangue , Metilenotetra-Hidrofolato Redutase (NADPH2)/deficiência , Triagem Neonatal/métodos , Espectrometria de Massas em Tandem/métodos , Algoritmos , Homocisteína/sangue , Humanos , Recém-Nascido , Erros Inatos do Metabolismo/diagnóstico , Metionina/sangue , Mutação , Fenilalanina/sangue , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...